Category: DMP

  • DMP 1102 Wireless Universal Transmitter Installation Guide

    DMP 1102 Wireless Universal Transmitter Installation Guide

    1102 WIRELESS UNIVERSAL TRANSMITTER Installation Guide Figure 1:1102 Universal Transmitter DESCRIPTION The 1102 Universal Transmitter provides an onboard terminal block as a single input, typically used with external door or window contacts. The contact operates as a single zone.1102 features the Disarm/ Disable operation to save battery life. When this option is enabled, Zone Tripped…

  • DMP 1141 Wireless Wall Button Installation Guide

    DMP 1141 Wireless Wall Button Installation Guide

    1141 WALL BUTTON TRANSMITTERInstallation Guide Figure 1:1141 Wireless Wall Button DESCRIPTION The 1141 Wall Button is a one-button wireless transmitter. The transmitter may be used for a variety of applications such as arming, disarming, toggling an output, activating a Z-Wave favorite, or activating a panic or emergency alarm. 1141 features a water-resistant button (when installed…

  • DMP 1122 Wireless PIR Motion Detector Installation Guide

    DMP 1122 Wireless PIR Motion Detector Installation Guide

    1122 WIRELESS PIR MOTION DETECTORInstallation Guide DESCRIPTION The 1122 Wireless PIR Motion Detector uses passive infrared technology to detect motion in a wide angle lens pattern.1122 also features a wall tamper, internal case tamper, survey LED, low battery indicator, adjustable sensitivity, and pulse count.Disarm/disable and pet immunity up to 55 pounds are available for panels…

  • DMP 1106 Series Wireless Universal Transmitters Installation Guide

    DMP 1106 Series Wireless Universal Transmitters Installation Guide

    DMP 1106 Series Wireless Universal Transmitters Installation Guide DESCRIPTION The 1106 Series Wireless Universal Transmitters are wireless, two-input transmitters typically used for door and window applications. The 1106E  features 128-bit AES encryption. The 1106 Series provides a cover tamper, magnetic reed switch, and an on-board terminal block to allow for external contact wiring. Both contacts,…

  • DMP ADEMCO Interface Module 738A Installation Guide

    DMP ADEMCO Interface Module 738A Installation Guide

    DMP ADEMCO Interface Module 738A Installation Guide Installation Guide DESCRIPTIONThe 738A Ademco Interface Module allows you to interface Ademco 5881 wireless receivers with the XR150/XR550 Series and XT30/XT50 Series panels.See “Compatibility” for specific firmware levels. The module provides up to 32 supervised, programmable zones of Ademco wireless transmitters.The module supports the Armed, Alarm, and Ready…

  • DMP 1183 Series Wireless Heat Detector Installation Guide

    DMP 1183 Series Wireless Heat Detector Installation Guide

    1183 SERIES WIRELESS HEAT DETECTOR1183 INSTALLATION GUIDEDIGITAL MONITORING PRODUCTSInstallation Guide DESCRIPTION The 1183 Series is available in two models: 1183-135F and 1183-135R.The 1183-135F is a fixed temperature detector that reacts to heat by responding to the fixed 135° temperature setting. When activated, an alarm is sent to the control panel. The 1183-135F model has a…

  • DMP 1158 Wireless Eight-zone Input Module Installation Guide

    DMP 1158 Wireless Eight-zone Input Module Installation Guide

    1158 WIRELESS EIGHT-ZONEINPUT MODULEInstallation Guide Figure 1:1158 DESCRIPTION When a DMP panel is installed in a location with an existing non-DMP panel, the 1158 Wireless EightZone Input Module can be used to convert up to eight existing normally closed, hardwired zones into wireless zones. This allows the new DMP panel to communicate with existing zones.…

  • DMP 1154 Wireless Four-zone Input Module Installation Guide

    DMP 1154 Wireless Four-zone Input Module Installation Guide

    1154 WIRELESS FOUR-ZONEINPUT MODULEInstallation Guide DESCRIPTION The 1154 Wireless Four-Zone Input Module is designed to convert up to four existing normally closed, hardwired zones (such as motion sensors, door & window contacts, etc.) into wireless zones.When a DMP panel is installed in a location with an existing nonDMP panel, then 1154 can be connected to…

  • DMP 738I ITI – Interface Module Installation Guide

    DMP 738I ITI – Interface Module Installation Guide

    DMP 738I ITI – Interface Module Installation Guide ABOUT THE 738I ITI™ The 738I ITI™ Wireless Interface Module allows you to interface ITI™ SuperBus™ 2000 Series Wireless receivers with the DMP XT30/XT50 Series and XR150/XR550 Series panels. This module allows up to 96 supervised, programmable zones of ITI wireless transmitters when used with the ITI™…

  • DMP 1122 International Wireless Motion Detector Installation Guide

    DMP 1122 International Wireless Motion Detector Installation Guide

    1122 INTERNATIONAL WIRELESS MOTION DETECTORInstallation Guide DESCRIPTIONThe 1122INT Wireless PIR Motion Detector uses passive infrared technology to detect motion in a wide-angle lens pattern. The 1122INT features 128-bit AES encryption.The motion detector features a wall tamper, internal case tamper, survey LED, low battery indicator, adjustable sensitivity, and pulse count.Disarm/disable and pet immunity up to 55…