Category: Bard

  • Bard Dehumidification Refrigerant Reheat Circuit Installation Guide

    Bard Dehumidification Refrigerant Reheat Circuit Installation Guide

    Bard Dehumidification Refrigerant Reheat Circuit This model provides a unique dehumidification circuit for periods of low outdoor ambient temperature and high indoor humidity conditions.Refer to Specification Sheet S3588 for the standard features of the base units and this manual for electrical data. Dehumidification Circuit The dehumidification refrigerant reheat circuit is controlled by a dehumidification valve…

  • Bard MC5300/MC5600 Series Controller Firmware Update Instructions

    Bard MC5300/MC5600 Series Controller Firmware Update Instructions

    Bard MC5300/MC5600 Series Controller Firmware Update Instructions These instructions detail the firmware update process for the MC5300 and MC5600 Series controllers. Tools and Supplies Needed MC5300 or MC5600 controller Computer/laptop Micro SD card adapter (if needed) Update file (can be found @ http://www.bardhvac.com/software-download/)This file will need to be unzipped after download.File to be transferred will…

  • Bard Commercial Room Ventilator CHCRV-5 Installation Guide

    Bard Commercial Room Ventilator CHCRV-5 Installation Guide

    INSTALLATION INSTRUCTIONS Commercial Room Ventilator with ExhaustModel: CHCRV-5For Use with Bard C**H Series 3, 4 & 5 Ton2-Stage Wall Mount Heat PumpsandW38H, W43H, W49H & W61HT36H, T42H, T48H & T60HT36S, T42S, T48S & T60S C36H, C42H, C48H & C60HSingle Stage Wall Mount Heat Pumps Bard Manufacturing Company, Inc.Bryan, Ohio 43506www.bardhvac.com Manual: 2100-450MSupersedes: 2100-450LDate: 3-1-21 GENERAL…

  • Bard Carbon Dioxide Transmitter 8403-096 Instructions

    Bard Carbon Dioxide Transmitter 8403-096 Instructions

    Bard Carbon Dioxide Transmitter 8403-096 Instructions SUPPLEMENTAL INSTRUCTIONS 8403-096 Carbon Dioxide Transmitter (Dwyer® CDT-2N40-LCD-RLY 002 Sensor) Series CDT Wall Mount Carbon Dioxide Temperature Transmitters accurately monitor the CO2 concentration and temperature in schools, office buildings, and other indoor environments to help achieve LEED® certification. For increased sensor life, a single-beam dual-wavelength nondispersive infrared (NDIR) sensor…

  • Bard IWSR-A23 I-TEC Wall Sleeve for Recessed Wall Louvers Installation Guide

    Bard IWSR-A23 I-TEC Wall Sleeve for Recessed Wall Louvers Installation Guide

    INSTALLATION INSTRUCTIONSI-TEC® Wall Sleeve for Recessed Wall LouversModels: IWSR-A23 IWSR-B23 IWSR-C23 Bard Manufacturing Company, Inc.Bryan, Ohio 43506www.bardhvac.com Manual: 2100-756BSupersedes: 2100-756ADate: 9-24-21 Getting Other Information and Publications These publications can help with the installation of the air conditioner or heat pump. They can usually be found at the local library or purchased directly from the publisher.…

  • Bard CompleteStat Controller Installation Guide

    Bard CompleteStat Controller Installation Guide

    Bard CompleteStat Controller NOTEScreenshots shown in this manual reflect default settings (when applicable). INSTALLATION IMPORTANT: For optimum temperature sensor performance, the Bard CompleteStat must be mounted on an interior wall and away from any heat sources, sunlight, windows, air vents, air circulation obstructions and/or any other cause of erratic or false temperature sensing. Thermostat covers…

  • Bard 8403-062 Remote Indoor Air Temperature Sensor Instructions

    Bard 8403-062 Remote Indoor Air Temperature Sensor Instructions

    Bard 8403-062 Remote Indoor Air Temperature Sensor Instructions Installation Carefully read and follow entire instructions before starting the installation. Follow all local electrical codes during installation. All wiring must conform to local and national electrical codes. Improper wiring or installation may damage the controller sensor. The 8403-062 Remote Indoor Temperature Sensor is a 10k-ohm Type…

  • Bard MicroSD Card Instructions

    Bard MicroSD Card Instructions

    Bard MicroSD Card Instructions The following instructions detail the process for replacing the MicroSD card in MC5300 and MC5600 Series controllers. Kit 8620-324 includes the following: 128 MB Micro SD card Supplemental Instructions 7960-901 Instructions Disconnect power to the controller by unplugging the 5-pin connector plugged into the back of the display (see Figure 1).…

  • Bard 8620-344 Wall Mount UV-C LED Field Kits Instructions

    Bard 8620-344 Wall Mount UV-C LED Field Kits Instructions

    SUPPLEMENTAL INSTRUCTIONS8620-343 & 8620-344Wall Mount UV-C LED Field Kits WARNINGElectrical shock hazard.Disconnect the remote electric power supply or supplies before servicing. Failure to do so can result in serious injury or death. WARNINGExposed moving parts.Disconnect all electrical power before servicing.Failure to do so can result in severe injury or amputation.CAUTIONSharp metallic edges.Take care and wear…

  • Bard W42AC wall-mount units Instructions

    Bard W42AC wall-mount units Instructions

    SUPPLEMENTAL INSTRUCTIONS CMC-35 Alarm Relay Kit The CMC-35 is a field-installable alarm relay kit. This alarm relay kit is only for use on R-410A refrigerant systems.The CMC-35 kit is for use with Bard models W42AC, W42HC, W48AC, W48HC, W60AC, W60HC, and W72AC wall-mount units.The CMC-35 kit consists of: 7960-857 Supplemental Instructions  910-2069 Relay Assembly  1012-065…