Category: TRACEABLE

  • TRACEABLE 15-079-641 Hi-Temp Datalogging Thermometers with Remote Notification Instructions

    TRACEABLE 15-079-641 Hi-Temp Datalogging Thermometers with Remote Notification Instructions

    CONTROLS WiFi: Enables WiFi capabilities.SET: Use to set: date/time, alarm settings (if WiFi has not been configured).UP: Adjusts setting up in the SET menu.DOWN: Adjusts setting down in the SET menuCHANNEL SELECT: Select which channel to display or select dual-channel view mode to view both channels.PLAY/PAUSE: In single-channel view mode, select second line display: current…

  • TRACEABLE Memory Hygrometer/ Thermometer Instructions

    Memory Hygrometer/ Thermometer MEMORY HYGROMETER/ THERMOMETER INSTRUCTIONS 10 to 95% RH ­20 to 50°C (­20 to 122°F)2%RH midrange 4%RH otherwise50°C WARRANTY, SERVICE, OR RECALIBRATION For warranty, service, or recalibration, contact:TRACEABLE® PRODUCTS 12554 Old Galveston Rd. Suite B230 Webster, Texas 77598 USA Ph. 281 482-1714 · Fax 281 482-9448E-mail · www.traceable.comTraceable® Products are ISO 9001:2018 QualityCertified…

  • TRACEABLE 4559274 Infrared Thermometer with Memories-Alarm Instructions

    TRACEABLE 4559274 Infrared Thermometer with Memories-Alarm Instructions

    TRACEABLE 4559274 Infrared Thermometer with Memories-Alarm SPECIFICATIONS Range –4 to 788°F / –20 to 420°C Resolution 1° Accuracy ±2° C, ±2% Alarm Audio Emissivity 0.3 to 1.0 Sampling Rate 0.5 second Features Backlight, 9 Point Memory, Laser Targeting, Programmable Alarm Included Lanyard and carrying case Battery 9-Volt CONTROLS AND INDICATORS MODE key. Temperature display mode…

  • TRACEABLE 1034CC Dual-Display Digital Stopwatch Instructions

    TRACEABLE 1034CC Dual-Display Digital Stopwatch Instructions

    COUNTDOWN TIMER MODEMaximum setting time: 9 Hours, 59 Minutes, and 59 seconds.BATTERY LIFE INDICATORThe battery life indicator (upper left corner) on the display will be on when the battery needs to be replaced. Lithium battery CR 2032 or equivalent is used.IF THERE IS ANY IRREGULAR SEGMENTS OR MALFUNCTIONS, PLEASE HOLD DOWN THE 4  BUTTONS TO RESET…

  • TRACEABLE Jumbo DGIT Stopwatch Instructions

    TRACEABLE Jumbo DGIT Stopwatch Instructions

    TRACEABLE Jumbo DGIT Stopwatch . SPECIFICATIONS Capacity: 23 Hours, 59 Minutes, 59 Seconds. Resolution: 1/100th second (> 30 minutes) 1 second (< 30 minutes) SINGLE ACTION TIMING Press the MODE button until the unit displays the stopwatch mode (indicated by a flashing bar under SU). Press the LAP/SPLIT/RESET button to clear the display to zero.…

  • TRACEABLE 300 Memory Stopwatch Instructions

    TRACEABLE 300 Memory Stopwatch Instructions

    TRACEABLE 300 Memory Stopwatch SPECIFICATIONS Display: ¼” digits, 3-line LCD display Range: 9 hrs, 59 min, 59 sec, 99/100 Resolution: 1/100 sec Accuracy: 0.001% Features: Continuous Timing, Lap/Split Timing, Countdown/Count up Timing, Speed Timing, Stroke Timing, Pacer Timing, Time/Calendar display, Daily Alarm CONTROLS Listed below are the unit’s buttons along with their function in the…

  • TRACEABLE Decimal Stopwatch Instructions

    TRACEABLE Decimal Stopwatch Instructions

    TRACEABLE Decimal Stopwatch GENERAL FEATURES 4 buttons operation Large LCD display with contrast adjustment 12/24 hour display Normal time and chime Daily alarm Full 1/100 second chronograph with working range from 0 to 19 hr. 59 min. 59.99 seconds with 100, 300 or 500 memory records of split and lap time. Recall function for recorded…

  • TRACEABLE Jumbo Display Dial Thermometer Instructions

    TRACEABLE Jumbo Display Dial Thermometer Instructions

    TRACEABLE Jumbo Display Dial Thermometer SPECIFICATIONS Range –58 to 302°F / –50 to 150°C Accuracy Cat# 4049 ±1°C between –20 and 100°C Cat# 4355- ±1°C between –20 and 100°C Cat# 4374- ±0.3°C (–20 and 100°C) otherwise ±1°C Resolution 0.1° above –20° and below 200° 1° below –20° and above 200° Sampling Rate: 1 second ULTRATM…

  • TRACEABLE 4029 Dual-Channel Thermometer Instructions

    TRACEABLE 4029 Dual-Channel Thermometer Instructions

    TRACEABLE 4029 Dual-Channel Thermometer SPECIFICATIONS Circuit ONS Circuit Custom one– chip of microprocessor LSI with thermocouple linearity correction circuit Display Dual function meter’s display, 13 mm (0.5”), Super large LCD display with annunciator Measurement Two channel temperature input (T1, T2), differential temperature measurement (T1-T2), °C/°F, 0.1°/1° degree Measurement Range –50 to 1230°C (–58 to 1999°F)…

  • TRACEABLE Wide Range Thermometer User Manual

    TRACEABLE Wide Range Thermometer User Manual

    TRACEABLE® WIDE RANGE THERMOMETER INSTRUCTIONS SPECIFICATIONS Thermocouple: Type-KRange: –328 to 2498 °F / –200 to 1370 °CResolution: 0.1° from -328 to 990°F/-200 to 640°C1° from 990 to 2498°F / 640 to 1370°CAccuracy: ±1° C TEMPERATURE MEASUREMENT Insert the probe plug into the socket at the top of the meter. The plug and sockets are keyed…